Bearing Housing Repair
A bearing housing was very badly worn on both the
inside and outside. It was repaired without being dismantled. The roller bearing was fixed in the housing.
All gaps were sealed with Metal-Tech RG. After these were sealed, Metal Tech FG was injected with a
cartridge between the roller bearing and the bearing housing. The bearing housing was back in service in a few hours. |
 |
 |
|

|
 |
Concrete Joint Repair
Floor-Tech RS and Seal-Tech SS were used to repair a movement joint between a building and the external concrete hardstanding. |
 |
 |
|

|
 |
Concrete Stairway Repair
A complete repair of this Recreation Area's stairway was required. Thorough cleaning and roughening of the surface of the repair area was carried out before the application of a tack coat of Grano-Tech Primer. The damaged areas were then rebuilt using Grano-Tech which
is our three component, solventfree, heavy duty epoxy repair
mortar. The entire surface of the concrete stairway was then
coated with Floor-Tech FB. |
 |
 |
|

|
 |
Conveyor Belt Repairs
Thorex Flexi-Tech products are ideal for the repair of worn and damaged conveyor belts. Two layers of Thortex Reinforcement Tape were embedded into Flexi-Tech 60 RG and completely encapsulated. |
 |
 |
|

|
 |
Conveyor Repair
Flexi-Tech 60 RG was used to repair a conveyor belt had ripped partly due to the sub-zero temperatures which it very often had to operate in and also due to general wear and tear. |
 |
 |
|

|
 |
Extreme Concrete Repair
Floor-Tech PR was used to repair extensive areas of the Heathrow Airport taxiway, one of the busiest airports in the world. The areas for repair were only
available for 7 hours throughout the night and all repairs had to be cured to a
compressive strength of 12,000 psi. The repairs proved a complete success with the regular flow of aircraft using the taxiway the following morning. |
 |
 |
|

|
 |
Gutter Protection
The roof of this building has two 162 ft. long box gutters. The client required a long-term high performance protection system, which would waterproof and weatherproof the gutters. The reinforced Poly-Tech system was recommended for this application based on the fact that it is totally unaffected by ponding water or permanent immersion conditions. The surface of the box gutters was prepared ensuring the substrate was clean, dry and free from contamination. It was then primed with Uni-Tech MC Primer prior to the application of the Poly-Tech system. This comprised one coat of Poly-Tech into which Thortex Chopped Strand Matt was embedded, followed by a second coat of Poly-Tech.
|
 |
 |
|

|
 |
High Build Floor Protection
A heavy duty floor protection system suitable for
concrete floors operating in an aggressive industrial environment was required. The Floor-Tech HB system was chosen for this application over other coating
systems based on its ceramic enhancement. The dense concrete floor, totalling 3,090 sq. feet, was prepared by
captive-shot blasting and primed with Uni-Tech GP Primer. The primed substrate was then coated
with our two component, solventfree, ceramic-enhanced, high build epoxy coating Floor-Tech HB which offers optimum levels of adhesion, abrasion, impact and
chemical resistance. |
 |
 |
|

|
 |
Intake Pump Housing Refurbishment
Cerami Tech CR resurfacing and lining system and Chemi-Tech EP used to refurbish an intake pump badly cavitated due to years of service in a salt water environment. |
 |
 |
|

|
 |
Leaking Pipe Repair
On news year’s day this Drain
Commission had a bad leak on a 3 inch
“T” and had no replacement parts they
could use. Fortunately, they had
ordered USI Pipe Repair System 4 months
earlier. |
 |
 |
|

|
 |
Lining Of Storage Container
This container was used to store liquefied brown coal in a
briquette factory. The container was in need of relining to extend its working life and ensure no seepage of its contents out of the container. The entire surface was first blast cleaned and then two coats of Chemi-Tech UC were applied. The container was protected over five years ago and has not required relining since. |
 |
 |
|

|
 |
Roof Refurbishment
This section of roof had deteriorated over time and now required a cost-effective waterproofing system, which
would protect the building beneath. The roof was cleaned, dirt and debris removed and any damaged areas repaired. Poly-Tech WG was first applied to the substrate fully embedding Thortex Chopped Strand Matt followed by a second coat of Poly-Tech WG. |
 |
 |
|

|
 |
Secondary Containment Area Protection
The concrete walls and floor of this 150 ft × 150 ft × 15 ft secondary containment unit,
which houses a 60 ft high gasoline tank, had developed
cracks. Following a site survey, it was established that there were 52 vertical and horizontal cracks and joints to seal which totalled over 4800 linear feet. The areas to be repaired were grit blasted using an angular abrasive
and treated with Flexi-Tech Primer. Flexi-Tech 80 EG was then applied. |
 |
 |
|

|
 |
Stairway Repairs
The staircase in this building, protected by the state as a unique architectural construction, had deteriorated badly and was to be returned it to its original appearance. The damaged areas were rebuilt with Grano-Tech, the high performance concrete repair product. |
 |
 |
|

|
 |
Tank Room Protection
Uni-Tech GP Primer and Wall-Tech WB, our water-based epoxy coating was used to refurbish one of the tank rooms at a brewery. Wall-Tech WB has been developed for use on internal wall surfaces and is ideal for applications in food and beverage processing establishments, where low odour and hygiene conditions are important. Uni-Tech UV system was used to refurbish the storage tank dish ends. Chemi-Tech PW was used to protect the internal surfaces of the tanks. |
 |
 |
|